FEATURES ::
Two-wire compact transmitter
Stainless steel diaphragm
Measuring range: 0.1-400 bar, -1 bar
Scalable analogue output
Programmable damping
Level and pressure management
Secondary lightning protection
High overload capability
High accuracy <0.25%
Wide temperature ranges
HART communication
Explosion-proof models
SPECIFICATIONS ::
Power supply: 10-36V DC
Ambient temperature: -25 °C to +70 °C
Medium temperature: -25 °C to +125 °C
Pressure: 0.1-400 bar, -1 bar
Outputs: 4-20 mA, HART
Process connection: 1/2'', 1'', 11/2'' process connection or hygienic fitting
Protection: IP 65
Approvals: ATEX II 1 G EEx ia IIC T6...T4